2001-Present Jacuzzi Hot Tub Spas Topside ERROR Codes
Jacuzzi Topside Error Codes (2001-Present)
Sensor Errors
Code | Reason | Cause | Fix | Parts Needed |
---|---|---|---|---|
Sn1 | High Limit Sensor | High limit sensor reading is outside normal range. | Replace the high limit sensor. | Replace OH Sensor |
Sn2 | Temperature Sensor | Temperature sensor reading is outside normal range. | If water is not hot, replace the temperature sensor. | Replace Temp Sensor |
Sn3 | Temperature Sensor | Temperature sensor values are incorrect. | Replace the temperature sensor. | Replace Temp Sensor |
Water Flow Issues
Code | Reason | Cause | Fix | Parts Needed |
---|---|---|---|---|
FL1 | Low/No Flow | Water flow is insufficient; heater disabled. |
|
Flow switch, pressure switch, pump |
FL2 | Failed Switch | Flow/pressure switch malfunction. | Replace the flow switch (24/7 circ pump models) or pressure switch (models with #1 jet pump). | Flow switch or pressure switch |
Temperature Warnings
Code | Reason | Cause | Fix | Parts Needed |
---|---|---|---|---|
COOL | Low Temp | Water is 20°+ below set temperature. | If heating, wait. If not, check heater or PCB. | Heater element or PCB |
ICE | Freeze Risk | Spa is in emergency mode to prevent freezing. | Ensure heater is working. If not, troubleshoot heater or PCB. | Heater element or PCB |
OH | Overheat | Water exceeds 112°F. |
|
Temp sensor, OH sensor, or PCB |
⚠️ System Errors
Code | Reason | Cause | Fix | Parts Needed |
---|---|---|---|---|
---- | Watchdog | PCB detected an unidentifiable issue. | Replace temperature sensor first (common fix). If unresolved, check other components. | Temp sensor or PCB |
HOLD | Overloaded Input | Too many button pressed too fast. | Wait and press buttons more slowly. | None |
Thermometer | PCB Overheat | PCB box is overheating. | Allow PCB to cool; error will reset automatically. | None |
PnL | Panel Connection | Loose/damaged topside panel connection. | Power off spa, unplug, and reconnect the topside panel. | Check wiring connections |
General Troubleshooting Tips
- Turn Power Off First: Always turn off power before unplugging/reconnecting components.
- Sensor Checks: Most errors (e.g., Watchdog, OH) are often resolved by replacing temperature sensors.
- Seasonal Issues: Overheating (OH) in summer may require propping the cover open for ventilation.
- Call Live Tech 858-210-8062. Have ready Year, Make, Model of your Hot Tub
May 7th 2025
Recent Posts
-
LocF and LocP Error Code Hot Tub Spa Topside Control Panel
Understanding the "LocF" and LocP Errors on Your Hot Tub Control Panel The "LocF" message …Jun 28th 2025 -
SpaStore.com Guide to Hot Tub Spa Electric Heater Troubleshooting
SpaStore.com Guide to Hot Tub Spa Electric Heater Troubleshooting Diagnosing Failures, Causes & …Jun 26th 2025 -
How Much Does It Cost To Repair A Portable Hot Tub Spa In Town?
Hot Tub Service Rates: Trip Charge - To Ring the doorbell $175 First hour: $175.00 Additiona …Jun 26th 2025