2001-Present Jacuzzi Hot Tub Spas Topside ERROR Codes
Jacuzzi Topside Error Codes (2001-Present)
Sensor Errors
| Code | Reason | Cause | Fix | Parts Needed |
|---|---|---|---|---|
| Sn1 | High Limit Sensor | High limit sensor reading is outside normal range. | Replace the high limit sensor. | Replace OH Sensor |
| Sn2 | Temperature Sensor | Temperature sensor reading is outside normal range. | If water is not hot, replace the temperature sensor. | Replace Temp Sensor |
| Sn3 | Temperature Sensor | Temperature sensor values are incorrect. | Replace the temperature sensor. | Replace Temp Sensor |
Water Flow Issues
| Code | Reason | Cause | Fix | Parts Needed |
|---|---|---|---|---|
| FL1 | Low/No Flow | Water flow is insufficient; heater disabled. |
|
Flow switch, pressure switch, pump |
| FL2 | Failed Switch | Flow/pressure switch malfunction. | Replace the flow switch (24/7 circ pump models) or pressure switch (models with #1 jet pump). | Flow switch or pressure switch |
Temperature Warnings
| Code | Reason | Cause | Fix | Parts Needed |
|---|---|---|---|---|
| COOL | Low Temp | Water is 20°+ below set temperature. | If heating, wait. If not, check heater or PCB. | Heater element or PCB |
| ICE | Freeze Risk | Spa is in emergency mode to prevent freezing. | Ensure heater is working. If not, troubleshoot heater or PCB. | Heater element or PCB |
| OH | Overheat | Water exceeds 112°F. |
|
Temp sensor, OH sensor, or PCB |
⚠️ System Errors
| Code | Reason | Cause | Fix | Parts Needed |
|---|---|---|---|---|
| ---- | Watchdog | PCB detected an unidentifiable issue. | Replace temperature sensor first (common fix). If unresolved, check other components. | Temp sensor or PCB |
| HOLD | Overloaded Input | Too many button pressed too fast. | Wait and press buttons more slowly. | None |
| Thermometer | PCB Overheat | PCB box is overheating. | Allow PCB to cool; error will reset automatically. | None |
| PnL | Panel Connection | Loose/damaged topside panel connection. | Power off spa, unplug, and reconnect the topside panel. | Check wiring connections |
General Troubleshooting Tips
- Turn Power Off First: Always turn off power before unplugging/reconnecting components.
- Sensor Checks: Most errors (e.g., Watchdog, OH) are often resolved by replacing temperature sensors.
- Seasonal Issues: Overheating (OH) in summer may require propping the cover open for ventilation.
- Call Live Tech 858-210-8062. Have ready Year, Make, Model of your Hot Tub
May 7th 2025
Recent Posts
-
The Best Place To Find And Buy Sundance Spas Parts
Buy Sundance Spa Parts Online | SpaStore.com If you own a Sundance Spa, finding the right replacemen …Dec 11th 2025 -
How To Remove a Coast Spas Filter
Regularly cleaning your filter is essential for maintaining clean water and optimal spa performance. …Nov 13th 2025 -
Troubleshooting a Spa That Isn't Heating
Follow this logical, step-by-step guide to efficiently diagnose a no-heat issue.Step 1: Check the "H …Nov 12th 2025