J-300 Series (2014+)

Jacuzzi J-300 Series (2014+) Troubleshooting

This page covers Jacuzzi J-315, J-325, J-335, J-345, J-355, J-365, J-375, and J-385 hot tubs built in 2014 or later with the LED control panel. Find your error code or problem below to see what it means, what you can safely check yourself, and which part fixes it.

Reviewed by the Spa Store parts team, serving hot tub owners since 1994.

Is My Hot Tub a 2014+ Model?

When you turn the power on, a 2014+ J-300 control panel briefly shows the software version number, then lights up "888" to test the display, then shows the water temperature. The 2-pump models (J-335 through J-385) have two jets buttons; the 1-pump models (J-315 and J-325) have one. [Add your team's tip on where to find the model and serial number label.]

Error Codes and Display Messages

Display What it means Can I fix it? Guide
FL1 No water flow detected while the circulation pump is running. The heater shuts off. Often yes: check the filter, water level, and skimmer first. FL1 & FL2 guide
FL2 The flow switch reports flow while the pump is off. The heater shuts off. Usually needs a new flow switch. FL1 & FL2 guide
SN1 The high-limit sensor (which monitors water temperature inside the heater) has failed or been disconnected. The heater shuts off. Needs a technician to test the sensor. SN1 & SN2 guide
SN2 The water temperature sensor has failed or been disconnected. The heater shuts off. Needs a technician to test the sensor. SN1 & SN2 guide
OH The water has overheated to 116°F. Do not get in. The spa runs a pump for a few minutes to cool down. Check the water with a thermometer, then call a technician if it keeps happening. OH overheat guide
- - - (three dashes) The safety "watchdog" detected 118°F or a serious fault and shut the whole system down. Do not get in. Needs a technician. Watchdog guide
COL The water is 20°F or more below your set temperature, so the spa is heating automatically. No action needed. This is normal after a refill.
ICE The water dropped below 55°F, so freeze protection is running the pumps and heater until it reaches 65°F. No action needed. Freeze protection guide
CF Filter cleaning reminder. The display alternates between CF and the water temperature. Yes: clean or replace the filters, then reset the timer. Filter guide
blb Time to replace the CLEARRAY UV bulb. The display alternates between blb and the water temperature, and the CLEARRAY light blinks. Yes: replace the bulb (yearly) and reset the timer. CLEARRAY guide
LOC A lock mode is on. Some buttons or menus are disabled. Yes: unlock it in the Menu settings.

Common Problems

  • Hot tub not heating, or not heating enough
  • Heats sometimes, then stops (intermittent heating)
  • Nothing works or the control panel is blank
  • Circulation pump not running, or turning on and off
  • No jets
  • Weak or surging jets
  • Jets pump runs, then shuts off by itself
  • Jets pump hums but won't start
  • Breaker or GFCI keeps tripping
  • Lights won't turn on
  • CLEARRAY not working
  • Ozonator not working (optional equipment)
  • Filter cycle doesn't start

Normal Behavior That Looks Like a Problem

Many service calls turn out to be features working as designed. Check these first:

  • Jets turn off after 20 minutes. This saves energy. Press the jets button again for another 20 minutes.
  • Lights turn off after 2 hours. This is automatic.
  • The circulation pump stops on hot days. This is "summer logic": once the water is 95°F or warmer and 2°F above your set temperature, the circulation pump and CLEARRAY pause to avoid overheating.
  • The circulation pump turns on and off repeatedly. Some 2014 spas built before mid-July 2014 have a software glitch that causes this. A replacement software chip fixes it. See the circulation pump guide.
  • CLEARRAY or ozone shuts off when you use the jets. This is normal. They come back on about 5 minutes after the jets stop.
  • The temperature only goes up to 104°F. That's the standard maximum for safety. The factory setting is 100°F.

Factory Settings Quick Reference

Setting J-335 to J-385 J-315 and J-325
Temperature range 65°F to 104°F (default 100°F) 65°F to 104°F (default 100°F)
Primary filtration default 8 hours per day (PF2) 24 hours per day (PF6)
Secondary filtration default Off (SF0) Off (SF0)
CLEARRAY UV bulb Replace yearly Replace yearly

For J-315 and J-325 models, keep the 24-hour filtration setting. Running the circulation pump less than the factory recommends can cause water quality problems.

Common J-300 (2014+) Replacement Parts

Part Fits SKU
Control panel, 2-pump J-335 to J-385 5170066
Control panel, 1-pump J-315, J-325 3170066
Circuit board, 2-pump (North America) J-335 to J-385 3920066
Circuit board, 1-pump (North America) J-315, J-325 5920066
Flow switch J-335 to J-385 0400652
Flow switch J-315, J-325 2580656
Temperature / high-limit sensors All J-300 (2014+)
CLEARRAY UV bulb All J-300 (2014+)